Yanhua Mini ACDP “Device has Reach the Number of Calculations” Solution

Problem 1:

I need to clone an old BMW DME msd87.2 and I bought Yanhua Mini ACDP and Module 27 to do this. Why am I being controlled with limitations?

“decive has reached the number of calculations”
Decive Has Reach The Number Of Calculations 2

Problem 2:

I’m trying to read isn from BMW Msv80. Acdp said ‘the number of server calculations has exceeded the limit’.

Decive Has Reach The Number Of Calculations

 

Answer and solution:

The MSD8x MSV80 kind of DME’s need a server calculation that’s special. After a couple times it’s shuts you down. Up to 5 times per day.

Do it the next day.

If you are urgent, send the ACDP serial number to ACDP engineer to add 1-2 calculations.